GE Healthcare

 
GE Healthcare Life Sciences Part of GE Healthcare
  
items: total: checkout
Location: Home > Quantitative Imaging > Typhoon > Typhoon FLA 7000
Quantitative Imaging
Overview
Typhoon
Typhoon FLA 9500
Typhoon FLA 7000
ImageQuant Imagers

Typhoon™ FLA 7000 – the fast, versatile scanner for multiple users

Typhoon FLA 7000 is a fast laser scanner optimized for quantitative phosphorimaging, ECL Plus Westerns, visible single fluorescence and gel documentation. High speed, full functionality and ease of use make the system an appropriate choice for multiuser facilities.

Typhoon FLA 7000 provides full visible fluorescence with 473/532/635/650 nm excitation and up to 25 µm resolution for gel and blot imaging.


Typhoon FLA 7000 - Features and benefits


High speed scanning – scans a 20 x 40 cm gel in 2.5 minutes.
  • Less waiting and queues
  • High speed without compromising sensitivity
16-bit image data captured at up to 25 μm resolution
  • High resolution for accurate quantitation of closely spaced bands
Versatile range of applications: phosphorimaging, visible fluorescence, gel documentation
  • Imaging modes are available at any time without user modification
Four preinstalled lasers
  • Covers all the common applications in multiuser environments
Exchangeable filters in commercial standard format
  • Easily adapted to new fluorophores 20 x 24 cm scan area
  • Scans up to 8 blots measuring 8 x 10 cm for throughput and comparison




Technical specification

Detection modesFluorescence, chemifluorescence,
phosphorimaging, digitization
Excitation wavelengths473 nm (blue LD laser),
532 nm (green SHG laser),
635 nm (red LD laser),
650 nm (red LD laser
Radioisotopes3H, 14C, 32P, 33P, 35S sources
Dynamic range5 orders of magnitude
Bit depth16-bit
Max ScanningPhosphorimaging 20 x 40 cm
Fluorescence and digitization 24 cm x 40 cm
Pixel sizes25, 50, 100, 200 µm
Standard filtersIP (Phosphorimaging),
Y520, O580, R670
Dimensions (W × H ×D)940 x 556 x 360 mm
Weight62 kg
Line frequency50/60 Hz
Temperature15°C - 30°C
Humidity30% to 70% (no condensation)
Supply voltage 100 - 240 VAC ± 10%
Power consumptionApprox. 0.3 kVA

Imaging Application

Ratings are based on overall system performance including model-specific features, versatility, and sensitivity (limit of detection).
Blank fields indicate that data are not available.

++++ Superior performance
+++ High performance
++ Good performance
+ Acceptable performance
- Not applicable

Typhoon 9400/9410Typhoon FLA 9000Typhoon Trio/Tro+Typhoon FLA 7000
Storage Phosphor
32P, 125I, 14C, 35S, 33P, 3H ++++++++++++++++
Macroarray (radiolabeled) ++++++++++++-
Fluorescence—Proteins
CyDye DIGE Fluors
Cy2 +++++++++++-
Cy3 ++++++++++++-
Cy5 ++++++++++++-
ECL Plex Fluors
Cy2 +++++++++++-
Cy3 ++++++++++++-
Cy5 ++++++++++++-
Protein Stains
Deep Purple Total Protein Stain+++++++++++++++
SYPRO Ruby++++++++++++++++
NanoOrange™ (solutions) ++++++
Pro-Q Diamond (phosphorylated proteins)+++++++++++++
Pro-Q Sapphire 5 (Histidine-tagged proteins) +++++++++++++
ELISA
AttoPhos-++++-+++
Fluorescence—Nucleic acids
Cy3 and Cy5 +++++++++++++++
Alexa Fluor 532 and Alexa Fluor 633 +++++++++++++++
Nucleic acid stains
Ethidium Bromide (post stain) ++++++++++++++
Vistra Green, SYBR Gold, SYBR Green I & II ++++++++++++++
PicoGreen, RiboGreen +++-+++-
Chemifluoresence (enzyme-catalyzed)
ECL Plus Western blotting+++++++++++++++
ECF, AlkPhos direct ECF+++++++++++++
DDAO Phosphate+++++++++++++++
Multipurpose fluorescence
Cy2 +++++++++++++
Cy3 +++++++++++++++
Cy5 +++++++++++++++
Fluorescein, FAM, FITC, Alexa Fluor 488 +++++++++++++++
TET, HEX, ROX, TAMRA +++++++++++++
Other applications
GFP+++++++++++
Chemiluminescence
ECL +++-
ECL Plus +++-
ECL Advance +++-


Typhoon™

Data file

Typhoon FLA 7000 biomolecular imager pdf



Feedback Form