Superdex™ 75 / Superdex™ 200 Columns

  • High-resolution separations of proteins, peptides, and other biomolecules according to size.
  • Ideal for the polishing step in a purification procedure.
  • Separations in two ranges from Mr 3000 up to 600 000 (globular proteins).
  • Easy and predictable scale-up.
  • Excellent reproducibility and durability.
  • Tricorn™ High Performance columns* (10/300 GL) expertly packed with Superdex™.
Page down for more information

*   Tricorn columns have Valco fittings for ÄKTAdesign systems and are supplied with M6 connectors for FPLC System.
  PC columns require the use of Precision Column Holder (see Precision Column Holder) when used with standard chromatography systems.

Superdex™ 75 / Superdex™ 200 Columns

Technical Information


*Tricorn columns are design patented, see back of catalog for details.

TECHNICAL SPECIFICATIONS
Superdex™
Exclusion limit (Mr
Superdex™ 75 1 × 105 globular protein 
Superdex™ 200 1.3 × 106 globular protein 
Separation range (Mr
Superdex™ 75 3000-70 000 globular protein 
Superdex™ 200 10 000-600 000 globular protein 
Matrix  Spherical composite of cross-linked agarose and dextran 
Average particle size 13 μm 
Chemical stability Stable in all common buffers:
1 M acetic acid, 8 M urea,
6 M guanidine hydrochloride,
30% isopropanol, 70% ethanol,
1 M NaOH (for cleaning in place) 
pH stability 3-12 (working and long term), 1-14 (short term) 
Superdex™ 10/300 GL Columns (Tricorn)*
Bed dimensions 10 × 300 mm 
Recommended sample volume 25-250 μl 
Bed volume 24 ml 
Max. pressure   
Superdex™ 75 18 bar (261 psi, 1.8 MPa) 
Superdex™ 200 15 bar (217 psi, 1.5 MPa) 
Max. flow rate (H2O at 25°C) 
Superdex™ 75 1.5 ml/min 
Superdex™ 200 1.0 ml/min 
Theoretical plates > 30 000 m-1 
Superdex™ PC 3.2/30 Columns
Bed dimensions 3.2 × 300 mm 
Bed volume 2.4 ml 
Recommended sample volume 2-25 μl 
Max. pressure   
Superdex™ 75 24 bar (348 psi, 2.4 MPa) 
Superdex™ 200 12 bar (174 psi, 1.2 MPa) 
Max. flow rate (H2O at 25°C) 
Superdex™ 75 0.100 ml/min 
Superdex™ 200 0.100 ml/min 
Theoretical Plates > 30 000 m-1 
Storage 20% ethanol 
Storage temperature 4°C to 30°C 
* Columns are not suitable for use with ÄKTAprime™ plus system.

Click here to view this image in high resolution
Separation of standard proteins on Tricorn™ Superdex™ 200.

Click here to view this image in high resolution
Separation of monomer and dimer on Tricorn™ Superdex™ 75.