ÄKTAprime plus
Y Y Y Y
ÄKTAprime plus
ÄKTAprime plus is a chromatography system that performs simple purifications of tagged and untagged proteins
- Simple-to-use, preprogrammed templates covering all common techniques.
- Specific, quick, push-button methods for tagged protein purification.
- Optimal results with HiTrap, HiPrep and HiLoad prepacked columns.
ÄKTAprime plus is a compact one-step purification system that operates with most prepacked columns. For reliability and convenience, we recommend HiTrap, HiPrep or HiLoad columns that simply snap on to the side of the unit. The system has preprogrammed methods for typical applications such as purification of affinity tagged proteins, MAbs and sample clean-up. The flexible system can be used for more general purification tasks such as buffer exchange, gel filtration, ion exchange, HIC, and affinity chromatography.
The unit is compact and comprises a system pump, fraction collector, monitors for UV, conductivity and pH (optional). Valves for buffer selection, sample injection, gradient formation, and flow diversion are also integrated into the system. The system is not PC controlled but together with PrimeView software it offers continuous real-time monitoring and evaluation of results.
ÄKTAprime plus — Technical Specifications
| Complete Packsize | 1 Piece |
| Order Information | Excluding recorder |
| Application | Simple purification of tagged and untagged proteins |
| Flow rate | 0.1 ml/min-50 ml/min |
| Flow Rate | 0.1 ml/min-50 ml/min |
| Operating Pressure Max. | 1 MPa (145 psi) |
| Tubing i.d. [Flow Path] | 0.75 mm |
| Single Wavelength Detection | Mercury lamp and 254 and 280 nm filters included. Optional filters for 313, 365, 405, 436 and 546 nm. Optional zink lamp with 214 nm filter. |
| Multiple Wavelength Detection | No |
| Flow Cell Path Length | 2 mm (optional 5 mm) |
| pH Monitoring | 0-14 |
| Multiple Sample Injection | Optional, up to 2 samples |
| Autosampler Injection | No |
| Automatic Buffer Preparation | No |
| Buffer Selection | 2 buffer inlets |
| Multi-Step Purification | Optional, up to 2 steps |
| Relative Humidity | 20%-95% (non condensing) |
| pH Stability Long Term | 2-12 |
| pH Stability Short Term | 0-14 |
| Viscosity | max 10 cP (<10 ml/min), max 5 cP (>10 ml/min) |
| Width | 400 mm |
| Height | 530 mm |
| Depth | 450 mm |
| Weight | 13 kg |
| Voltage | 100-120/220-240 VAC |
| Protection Class |
IP 20 (Housing) IP 44 (Flow cell) |
| Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from GE Healthcare and connected only to other CE labeled GE Healthcare modules or other products as recommended. For regulatory details please see declaration of conformity. |
| Animation |
|---|
|
HiTrap: Connecting to a chromatography system (ÄKTA)
|
| Brochure |
|---|
|
Instrument Services for ÄKTA Systems
Summary
ÄKTA design is a platform of systems that gives you a competitive advantage in
biomolecule purification and separation. Our service engineers are specifically
trained to keep your ÄKTA system performing optimally, to save you time and
maximize productivity, allowing you to rely on your results and concentrate on
your research.
Close
|
|
Protein purification - at the touch of a button
Summary
ÄKTAprime plus is a compact liquid chromatography system designed for one-step
purification of proteins. Many protein purification activities can be carried
out just by pressing a button. The system is pure simplicity to operate, with
everything controlled from push buttons and an easy-to-navigate LCD display on
the front panel. With ÄKTAprime plus, reliable and convenient laboratory scale
protein purification is no longer pure imagination.
Close
|
|
Validation Services
Summary
GE Healthcare Validation Services supports efficient validation of your GE
Healthcare equipment compliance status. Our documentation supports your
equipment throughout its entire life cycle. When you choose GE Healthcare as
your provider of validation support, you can be confident that your equipment
is operating in a reliable, consistent, and GxP-compliant manner.
Close
|
|
ÄKTA Protein purification by design
Summary
With the ability to purify virtually any biomolecule, ÄKTA design platform can
handle the simplest and the toughest of challenges. It gives you speed, ease of
use, and flexibility whatever your purification application or scale. The
platform covers all major chromatographic and cross flow filtration techniques,
from the research laboratory to process development and manufacturing. Systems
in the ÄKTA platform work with intelligent UNICORN software, which makes it
simple to control every stage of your purification process. A broad range of
prepacked columns, media, and filters provides more options for optimum
results.
Close
|
| Cue card |
|---|
|
Strep(II)-tagged protein purification - ÄKTAprime™ Plus
|
|
ÄKTAprime plus
Summary
Contents
System Preparation
Buffer exchange on HiTrap Desalting
Buffer exchange on HiPrep 26/10 Desalting
Histidine-tagged protein purification,step elution
Histidine-tagged protein purification, gradient elution
IMAC purification - any metal
On-column refolding
GST-tagged protein purification
Strep(II)-tagged protein purification
MBP-tagged protein purification
MAb purification, step elution
MAb purification, gradient elution
IgM purification
Albumin removal
Removal of trypsin-like serine proteases
Anion exchange
Cation exchange
Method Templates value table
Close
|
| Handbook |
|---|
|
Affinity Chromatography, Principles & Methods
Summary
This handbook describes the role of affinity chromatography in the purification
of biomolecules, the principle of the technique, the media available and how to
select them, application examples and detailed instructions for the most
commonly performed procedures. Practical information is given as a guide
towards obtaining the best results.
Close
|
|
Gel Filtration, Principles and Methods
Summary
Gel filtration is a robust technique that is well suited to handling
biomolecules that are sensitive to changes in pH, concentration of metal ions
or co-factors and harsh environmental conditions. Separations can be performed
in the presence of essential ions or cofactors, detergents, urea, guanidine
hydrochloride, at high or low ionic strength, at 37 °C or in the cold room
according to the requirements of the experiment.This handbook describes the use
of gel filtration for the purification and separation of biomolecules, with a
focus on practical information for obtaining the best results. The media
available, selection criteria and examples with detailed instructions for the
most common applications are included, as well as the theoretical principles
behind the technique. The first step towards a successful separation is to
select the correct medium and this handbook focuses on the most up-to-date gel
filtration media and prepacked columns.The biocompatibility, stability and
utility of gel filtration media from Amersham Biosciences have made these
products the standard choice in practically every laboratory using the
technique. A wide variety of prepacked columns and ready to use media is
available.
Close
|
|
Ion Exchange Chromatography & Chromatofocusing, Principles and Methods
Summary
Ion exchange chromatography (IEX) has been used for separating biomolecules
since the 1960s and continues to play a major role in the separation and
purification of biomolecules. Today, IEX is one of the most requently used
techniques for purifying proteins, peptides, nucleic acids and other charged
biomolecules, offering high resolution and group separations with high loading
capacity. The technique is capable of separating molecular species that have
only minor differences in their charge properties, for example two proteins
differing by one charged amino acid. These features make IEX well-suited for
capture, intermediate purification, or polishing steps in a purification
protocol and the technique is used from microscale purification and analysis
through to purification of kilograms of product.
Close
|
|
Purifying Challenging Proteins - Principles and Methods
Summary
This handbook is intended for students and experienced researchers with an
interest in the isolation of integral membrane proteins, multiprotein
complexes, or in refolding proteins from inclusion bodies. The aim is to
present tools, strategies, and solutions available to meet the purification
challenges associated with these three classes of proteins.
Close
|
|
ÄKTA Laboratory-scale Chromatography Systems - Instrument Management Handbook
Summary
This handbook is focused on liquid chromatography systems used for protein
purification at research laboratory scale.
Beginners can use the handbook to obtain an overview of how purification
systems work and to learn about important considerations for achieving
successful results.
Experienced system users will also find valuable and detailed information on
different hardware modules.
Close
|
| Instruction/protocol |
|---|
|
UV lamp exchange
Summary
This instruction is valid for the Hg and Zn lamps.
Close
|
|
Valve INV-917
Summary
Valve INV-917 is a motorised rotary 7-port valve. The valve is used in ÄKTA™
design systems. It is powered from P-900 series system pump, and controlled
from UNICORN™ control system.
The valve has 3 positions used for:
- loading a sample loop
- injecting the sample onto the column
- washing the system pump.
In ÄKTAmicro™ system, INV-917 is also used as a Flow direction valve.
Features:
• Smooth flowpath minimises eluent or sample ”memory effect”.
• Flow rates up to 10 ml/min.
• All wetted parts are plastic PEEK.
Close
|
| Magazine |
|---|
|
Discovery Matters 5-2007
Summary
Table of contents
- Optimizing Ad-A-Gene assay parameters
- Two-step purification of a challenging membrane protein
- Enrichment of protein prior to LC-MS analysis
- Rapid purification of plasmid DNA
Close
|
|
Discovery Matters 6-2007
Summary
Table of contents
- Phi29 DNA polymerasebased technology for genomic DNA preparation
- Identifying chromosomal abnormalities in prostate cancer
- Multiplex assays using Ad-A-Gene Vectors
- Multiplex detection in Western blotting
- Chromatographic analysis of glycoproteins
Close
|
| Magazine article |
|---|
|
Low-cost, automated serial purification of histidine-tagged proteins (Discovery Matters 6, Aug 2007)
Summary
Automated chromatographic systems are of great help to structural genomics
programs involved in expressing and purifying numerous recombinant proteins. A
low-cost and automated process, using ÄKTAprime™ chromatography system is
described for the purification of histidine-tagged proteins.
Close
|
|
Monitoring expression of an E. coli membrane protein GFP-(His)8 fusion and purification using a combination of IMAC and gel filtration
Summary
An integral E. coli membrane protein GFP-(His)8-fusion was overexpressed,
solubilized, and purified to homogeneity. The GFP-moiety allowed direct
monitoring of the protein during all steps from expression to purification,
while the histidine tag expressed on the protein facilitated capture of the
protein of interest by immobilized metal ion affinity chromatography (IMAC) on
a HisTrap™ HP column.
Close
|
| Quality system certificate |
|---|
|
Certificate for ÄKTAprime plus (example)
|
| Software |
|---|
|
Downloadable installation program for USB-driver update for existing PrimeView 5 Installations
Summary
The driver improves the capabilty to use USB converters for connecting the
ÄKTAprime plus to the PrimeView 5 software.
Click on the file to download.
Close
|
| Software change description |
|---|
|
PrimeView v5.0 vs 1.0, Software change description
|
| User manual |
|---|
|
Fraction Collector Frac-950
Summary
This manual comprises two parts: a practical part (sections 1–5) and a
reference part (sections A-D). Sections 1–5 contain the necessary information
for operating the instrument. Fraction Collector Frac-950 is an automated
fraction collector for use in ÄKTA™ design chromatography systems. It is
intended to be operated as an integrated part of an ÄKTAdesign chromatography
system running UNICORN™ version 3.2, or higher. Frac-950 is equipped with an
accumulator to eliminate spillage at high flows. A drop sensor that can be used
to control tube change at low flows is also included.
Close
|
|
PrimeView 5.0
Summary
PrimeView™ is a complete control software package for supervision of ÄKTAprime™
automated liquid chromatography systems.
Close
|
|
ÄKTAprime™ plus Operating Instructions - Original instructions
Summary
The Operating Instructions provides you with the instructions needed to handle
the ÄKTAprime plus system in a safe way.
Close
|
Accessories
Select to expand the desired collection of accessories.
For accessories not displayed in this section, please contact your local GE Healthcare sales representative.
Accessories for ÄKTAprime plus
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | Superloop, 1/16" fittings, 10 ml | 18-1113-81 | GBP 415 | ||
| 2 | Superloop, 1/16" fittings (ÄKTAdesign), 50 ml | 18-1113-82 | GBP 492 | ||
| 3 | Superloop Complete, 150 ml, M6 fitting | 18-1023-85 | GBP 703 | ||
| 4 | Recorder REC-112 dual channel | 18-1132-33 |
|
Spare Parts
Select to expand the desired collection of spare parts.
For spare parts not displayed in this section, please contact your local GE Healthcare service representative.
Spare parts, front view
Figure. Front view.
Spare parts not indicated in the views
Spare parts for pump P-960
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | O-ring kit for P-960 | 28-9398-62 | GBP 108.43 | ||
| 2 | O-ring kit for P-960 | 28-9394-97 | GBP 143.82 | ||
| 3 | Outlet check valve, long | 18-1172-46 | GBP 175 | ||
| 4 | Outlet check valve, short | 18-1172-45 | GBP 136.5 | ||
| 5 | Inlet check valve, long | 18-1172-44 | GBP 119.99 | ||
| 6 | Inlet check valve, short | 18-1172-43 | GBP 155 |
Spare parts for UV, pH and conductivity recording
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 2 | Filter 254 nm | 18-0620-01 | GBP 340 | ||
| 2 | Filter 280 nm | 18-0621-01 | GBP 346 | ||
| 2 | Filter 214 nm | 18-0622-01 | GBP 359 | ||
| 2 | Filter 313 nm | 18-0623-01 | GBP 502 | ||
| 2 | Filter 365 nm | 18-0624-01 | GBP 486 | ||
| 2 | Filter 405 nm | 18-0625-01 | GBP 346 | ||
| 2 | Filter 436 nm | 18-0626-01 | GBP 438 | ||
| 2 | Filter 546 nm | 18-0627-01 | GBP 429 | ||
| 2 | Dummy Electrode, round tip | 18-1111-03 | GBP 72.49 | ||
| 2 | Clamp, conductivity cell | 18-1111-14 | GBP 30.99 | ||
| 2 | pH Electrode, round tip | 18-1111-26 | GBP 509 | ||
| 2 | pH Flow Cell | 18-1112-92 | GBP 399 | ||
| 2 | Recorder REC-112 dual channel | 18-1132-33 |
|
||
| 2 | pH Electrode with Cell and Holder, round tip | 18-1134-84 | GBP 909 | ||
| 2 | Signal Cable for ÄKTAprime and ÄKTAprime plus | 18-1141-35 | GBP 112.48 | ||
| 2 | Flow cell holder | 18-3055-87 | GBP 151 | ||
| 2 | Hg optics with 254 and 280 nm filters | 28-4042-23 | GBP 2,540 | ||
| 2 | Zn optics with 214 nm filter | 28-4042-24 | GBP 2,540 | ||
| 2 | Hg lamp and housing complete | 28-4042-25 | GBP 652 | ||
| 2 | Zn lamp and housing complete | 28-4042-26 | GBP 653 | ||
| 2 | Hg lamp | 28-9354-93 | GBP 589 | ||
| 2 | Zn lamp | 28-9365-72 | GBP 592 | ||
| 3 | UV Flow Cell, 5 mm | 18-1128-24 | GBP 835 | ||
| 3 | UV Flow Cell, 2 mm | 18-1128-25 | GBP 618 | ||
| 10 | Conductivity Flow Cell, 1/16" | 18-1111-05 | GBP 663 |
Spare parts for Fraction collector
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 8 | Tube Rack 40 × 30 mm, bowl, tube support, holder and guide | 18-1124-67 | GBP 493 | ||
| 8 | Tube Holder and Guide, 40 × 30 mm | 18-1124-68 | GBP 404 | ||
| 8 | Tube Rack Complete, 95 × 10–18 mm | 18-3050-03 | GBP 308 | ||
| 8 | Bowl | 18-3051-03 | GBP 72.1 | ||
| 8 | Tube Support | 18-3054-02 | GBP 63.04 | ||
| 8 | Tubing Holder | 18-6464-01 | GBP 45.18 | ||
| 8 | Eppendorf Tube Holder, for tube rack 175 × 12 mm | 18-8522-01 | GBP 59.88 | ||
| 8 | Funnel | 19-6044-01 | |||
| 8 | Drive sleeve | 19-6067-02 | GBP 46.63 | ||
| 8 | Tube Holder and Guide, 175 × 12 mm | 19-7242-02 | GBP 161 | ||
| 8 | Tube Rack 175 × 12 mm, bowl, tube support, holder and guide | 19-8684-03 | GBP 220 | ||
| 8 | Tube Holder and Guide, 95 × 10–18 mm | 19-8689-02 | GBP 114.52 | ||
| 11 | Flow diversion valve FV-903 | 18-1114-50 | GBP 235 |
Spare parts for IV-908
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 9 | Repair kit, valve IV-908 | 18-1109-07 | GBP 289 | ||
| Number Plates 0–9 | 18-1109-09 | ||||
| Mounting Bracket for Valves | 18-1109-11 | GBP 11.56 | |||
| Cable UniNet, L = 0.7 m | 18-1109-74 | GBP 87.2 |
Spare parts for Injection valve INV-907
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 5 | Repair kit, valve INV-907 | 18-1109-05 | GBP 306 | ||
| 5 | Injection Kit, INV-907 | 18-1110-89 | GBP 218 | ||
| 5 | Fill Port, INV-907 | 18-1127-66 | GBP 84.05 | ||
| 5 | Injection needles | 18-1801-42 | GBP 107.61 | ||
| 6 | Sample loop 100 µl | 18-1113-98 | GBP 87.2 | ||
| 6 | Sample loop 500 µl | 18-1113-99 | GBP 93.5 | ||
| 6 | Sample loop 1 ml | 18-1114-01 | GBP 99.81 | ||
| 6 | Sample Loop 2.0 ml, INV-907 | 18-1114-02 | GBP 98.76 | ||
| 6 | Sample loop, 10 µl | 18-1120-39 | GBP 27.84 | ||
| 6 | Sample Loop 5 ml, PEEK | 18-1140-53 | GBP 93.19 | ||
| Number Plates 0–9 | 18-1109-09 | ||||
| Mounting Bracket for Valves | 18-1109-11 | GBP 11.56 | |||
| Cable UniNet, L = 0.7 m | 18-1109-74 | GBP 87.2 |
Spare parts, Accessory box delivered with the system
The kit contains:
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | Tubing Cutter | 18-1112-46 | |||
| 2 | Fingertight Connector 1/16" Male for Tubing o.d. 1/16" | 18-1112-55 | GBP 51.48 | ||
| 3 | HiTrap/HiPrep, 1/16", male connector for ÄKTAdesign | 28-4010-81 | GBP 38.04 | ||
| 4 | Fingertight Union 1/16" Male/M6 Female | 18-1112-58 | GBP 79.85 | ||
| 5 | Union 1/16" Male - 1/16" Male, i.d. 0.5 mm | 18-1120-93 | GBP 44.65 | ||
| 6 | Connector 1/16" Male/Luer Female | 18-1112-51 | GBP 38.35 | ||
| 7 | Union 1/16" Female/M6 Male | 18-1112-57 | GBP 65.66 | ||
| 8 | Stop Plug 5/16" Male | 18-1112-50 | GBP 15.15 | ||
| 9 | Stop Plug 1/16" Male | 18-1112-52 | GBP 116.62 | ||
| 10 | Screw lid kit | 11-0004-10 | GBP 16.81 | ||
| 11 | Inlet filter holder kit | 11-0004-07 | GBP 57.26 | ||
| 12 | Short Column Holder, for columns 26 mm i.d. | 18-1113-17 | GBP 87.2 | ||
| 13 | Purge Kit P-950 | 18-1153-28 | GBP 48.85 |
Spare parts recommended to keep on site
Seals are considered as consumables and should be replaced annually or when needed. Please keep a set of each in your stock to prevent long downtime. For code numbers refer to the table below.
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | Inlet filter set | 11-0004-14 | GBP 37.3 | ||
| 2 | Online filter kit | 18-1027-11 | GBP 51.48 | ||
| 3 | On-line filter kit | 18-1130-23 | GBP 77.22 | ||
| 4 | Flow Restrictor FR-902 | 18-1121-35 | GBP 202 | ||
| 5 | Flow Restrictor FR-904 | 18-1119-63 | GBP 126.07 | ||
| 6 | pH Electrode, round tip | 18-1111-26 | GBP 509 | ||
| 7 | Mixer M-925 Mixing Chamber, 0.6 ml | 18-1118-90 | GBP 293 | ||
| 8 | Mixer M-925 Mixing Chamber, 2 ml | 18-1118-91 | GBP 274 | ||
| 9 | Repair kit, valve INV-907 | 18-1109-05 | GBP 306 | ||
| 10 | Repair kit, valve IV-908 | 18-1109-07 | GBP 289 |
Tubing
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | FEP Tubing, i.d. 1/8 in (3/16 in) | 18-1112-47 | GBP 38.35 | ||
| 2 | Tubing i.d. 0.5 mm, o.d. 1/16" | 18-1113-68 | GBP 26.79 | ||
| 3 | Tubing, 2 m, i.d. 0.75 mm, o.d. 1/16" | 18-1112-53 | GBP 38.35 | ||
| 4 | Tubing, 2 m, i.d. 1.0 mm, o.d. 1/16" | 18-1115-83 | GBP 34.14 | ||
| 5 | Sample Tubing Kit, i.d. 1.0 mm, o.d. 3/16", complete | 18-1115-77 | GBP 79.85 |
Unions, ferrule and stop plug
| # | Product Name | Product Code | Price | Qty | |
|---|---|---|---|---|---|
| 1 | Connector 3/16" Male for Tubing o.d. 3/16" | 18-1112-49 | GBP 99.81 | ||
| 2 | Ferrules for 3/16" o.d. Tubing | 18-1112-48 | GBP 44.65 | ||
| 3 | Tubing connector 1/8" | 18-1121-17 | GBP 87.2 | ||
| 4 | Ferrule for o.d.1/8" Tubing | 18-1121-18 | GBP 47.8 | ||
| 5 | Union 1/16" Female/M6 Male | 18-1112-57 | GBP 65.66 | ||
| 6 | Connector 1/16" Male/Luer Female | 18-1112-51 | GBP 38.35 | ||
| 7 | Fingertight Union 1/16" Male/M6 Female | 18-1112-58 | GBP 79.85 | ||
| 8 | Connector 5/16" Female - M6 Male | 18-1127-76 | GBP 25.25 | ||
| 9 | Union 1/16" Male - 1/16" Male, i.d. 0.25 mm | 18-1120-92 | GBP 11.56 | ||
| 10 | Union 1/16" female-1/16" female | 18-3855-01 | GBP 69.66 | ||
| 11 | Fingertight Connector 1/16" Male for Tubing o.d. 1/16" | 18-1112-55 | GBP 51.48 | ||
| 12 | Stop Plug 1/16" Male | 18-1112-52 | GBP 116.62 | ||
| 13 | Stop Plug 5/16" Male | 18-1112-50 | GBP 15.15 |